    Brand Name : Purescience
    Model Number : WH
    Certification : ISO9001 / ISO14001
    Price : USD300 - USD1000
    Payment Terms : L/C, T/T, D/P
    Supply Ability : 10000
    Delivery Time : 2-3 weeks
    • Product Details
    • Company Profile

    Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H

    Ultrasonic open channel flow meters non contact sensor for sewage treatment plant STP 200m3/h


    Product introduction

    The Open channel Ultrasonic Flowmeter is a high precision flow measurement instrument, which use Transit Time Ultrasound principle to measure the flow in a variety of Flumes, Weirs or Troughs.


    Features


    • With a fully independent intellectual property rights.
    • Has wide range of temperature compensation and original ERD interference intelligent identification system, measurement data stability, high precision.
    • Six groups flow condition all data sending 485 serial ports output, PC directly receive, decimal shows, the convenient user record and read archived.
    • Original "fluid flow correction system" that flow coefficient according to slot size and level to be automatic operation weir and timing compensation.
    • The blackout time time, the year/month/day/when/points/SEC, flow data, using the ferroelectric double backup storage 10 years off.
    • Original "measuring tank jam recognition alarm system" can detect liquid slag quality measurement slot throat and obstruction caused by measurement.
    • Precise date determined when the calendar clock Settings, display and cooperate with the memo and time axis to file information records.
    • Has 4~20 mA three wire system, RS485, switch quantity and so on many kinds of signal output function selection.
    • Using intelligent measuring high, digital calibration, the user installation calibration simple and quick.
    • The ultrasonic non-contact measurement with no moving parts, flow without components within, no block sensor fault hidden trouble.

    Sensors

    Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/HUltrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H

    Ultrasonic sensor Static pressure sensor


    Main technical index

    ModelWH
    Applicable weirsRight triangle weir slot (Open size: 500mm)
    Parshall flume (Larynx way width: 51mm, 76mm, 152mm, 228mm, 300mm)
    Rectangular weir (Opening size: 250mm, 500mm, 750mm )
    Flow rangedepending on weirs dimensions to be used, up to 335000 m3/hr
    Flow precision5% FS
    Level range1m
    Level precision0.5% FS
    Sensor blind area<300mm @ 25C
    Output4-20 mA, tri wires
    Display

    LCD display, include: four levels

    four transient flow

    Eight of the accumulative total flow

    16 calendar clock

    Work temperature50C , customized available
    Power supplyAC220V
    Outlet waySensor leads 20m, instrument standard plugs
    Installationinstrument wall mount, sensor grain installation M68x2.0, or clamp on
    ProtectionIP66 (sensor)

    Applications
    Measurement of water flow in Effluent, Waste Water, Rivers, Canals, Drains, Sewage, etc.


    Flow Totalizer parameters
    Flow measuring range: Depends on the size of the flume.
    Maximum Count: 9999999999
    Types of suitable weirs: Triangular weir, rectangular weir, Parshall flume, etc.
    Display accuracy: 1 count. Overall accuracy depends on the input signal. Different Weirs /
    flumes has different accuracies. A triangular weir has 1 to 2% flow error, a rectangular weir
    has 1 to 4% accuracy, a Parshall flume has 3% flow error, etc.
    Display: 2.8-inch LCD. Displays Height, Flowrate, Total Flow, etc.

    Output
    Voltage output: DC 12V or 24V
    Signal output: RS485/RS232; 4~20mA; 2 channel relay


    Troughs

    Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H

    Triangle weirs

    Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H

    Installation sample

    Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H


    Advantage

    The production capacity is 20000 ultrasonic converter and 100,000 ultrasonic sensor.

    Quality Ultrasonic Open Channel Ultrasonic Flow Meters / Ultrasonic Water Meter For Sewage Treatment Plant STP 200m3/H for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Xunhui Environment Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)