Sign In | Join Free | My himfr.com
Home > Ultrasonic Flow Meters >

Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine

    Buy cheap Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine from wholesalers
     
    Buy cheap Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine from wholesalers
    • Buy cheap Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine from wholesalers
    • Buy cheap Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine from wholesalers
    • Buy cheap Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine from wholesalers

    Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine

    Ask Lasest Price
    Brand Name : Purescience
    Model Number : YE-TUF2000FP
    Certification : ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
    Price : USD150-USD900
    Supply Ability : 500 sets per month
    Delivery Time : 3 weeks
    • Product Details
    • Company Profile

    Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine

    Fixed Inline ultrasonic flowmeters by transit time multi-liquid velocity determine for slurry | effluent | sewage


    General of ultrasonic flow meters

    The UFM Ultrasonic flowmeters can determine the velocity of a fluid flowing in a pipe by sound waves. When it's in no flow conditions, an ultrasonic wave's frequencies are transmitted into a pipe and its reflections from the fluid are the same. When it's under flowing conditions, the frequency of the reflected wave is different due to the Doppler effect. When liquid media moves faster, the frequency shift increases linearly. The transmitter processes signals from the transmitted wave and its reflections to determine the flow rate.

    The transit time type ultrasonic flowmeters can give and receive ultrasonic waves between the transducers in both the upstream and downstream in the pipe. While it's under no flow conditions, it takes the same time to travel upstream and downstream between the transducers. While it's under flowing conditions, the upstream wave will travel slower and take more time than the (faster) downstream wave. When the fluid moves faster, the difference between the upstream and downstream times increases. The transmitter processes upstream and downstream times to determine the flow rate.


    Data sheet

    Accuracy <1%

    Flow rate 0 - 10m/s, bi-direction

    Pipe diameter DN32 - DN6000 mm

    Liquid temperature -30℃ - 160℃

    Liquid type water, sea water, sewage, effluent, oil, alcohol, any single liquid that can

    transmit ulstrasonic wave

    Pipe material stainless steel, cast iron, copper, PVC, aluminum, fiber glass steel

    Output one way 4-20mA, one way OCT pulse, one way replay

    Input three way 4-20mA, PT1000 platinum resistor for heat measurement

    Communication RS485, MODBUS

    Data storage SD card

    Power supply DC8-36V / AC85-264V

    Protection IP65 (main body), IP68 (transducer)

    Humidity <85% RH

    Ambient temperature -20℃ - 60℃


    Description:

    The ultrasonic flowmeter is available with pipe type, clamp on and other options, it's designed for linear and bi-directional volumetric flow measurement of liquid. The measured flow datas can be output by standard analog or pulse or frequency. Through HMI user friendly operator interface, the unit can be set up for a wide range of applications. Next to actual volumetric flow measurement, the unit can be configured to perform flow totalization ( plus, minus, or sum). Measurement and output of the liquid sonic velocity can be configured too.


    Optionally the unit can be set to perform one of the following additional functions:

    • Calculate and output corrected standard volumetric or mass flow using external pressure & temperature inputs
    • Batch function
    • Heat function, combining T1, T2 and volume

    Metering Diagram

    Flow measurement Heat measurement

    Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine

    Reference chart

    Type

    Model

    Pipe dia (mm)

    Temperature

    Dimension (mm)

    Clamp on

    TS-2

    DN15-100

    -30-90℃

    45x25x32

    TM-1

    DN50-700

    -30-90℃

    64x39x44

    TL-1

    DN300-6000

    -30-90℃

    97x54x53

    Clamp on (high temperature)

    TS-2-HT

    DN15-100

    -30-90℃

    45x25x32

    TM-1-HT

    DN50-700

    -30-90℃

    64x39x44

    TL-1-HT

    DN300-6000

    -30-90℃

    97x54x53

    Insertion type

    TC-1

    DN80-6000

    -30-90℃

    190x80x55

    TC-2(lengthen)

    DN80-6000

    -30-90℃

    335x80x55

    Pipe type

    G3 (π type)

    DN15-25

    -30-160℃


    G2

    DN32/DN40

    -30-160℃


    G3

    DN50-6000

    -30-160℃



    Optional temperature transducer

    Specification

    Model

    Dia

    Temp.

    Water cut

    Accuracy

    Clamp-on temp. transducer Pt100

    CT-1

    >DN50

    -40-160℃

    No

    100+ 0.8℃

    Insertion temp. Transducer Pt100

    TCT-1

    Yes

    Insertion temp. Pt100 with pressure

    PCT-1

    No

    Insertion temp.Pt100 for small pipe D

    SCT-1

    <DN50

    Yes


    Industries

    • Chemicals
    • Petrochemicals
    • Oil & Gas
    • Heating, Ventilation & Air Conditioning (HVAC)
    • Power Plants
    • Water treatment

    Liquid type

    • Metering of cooling water
    • Demineralisedwater
    • Control of batching and blending operations
    • Mass flow measurement
    • Allocation measurement
    • District heating
    • Irrigation
    • Energy measurement

    Model Selection

    I

    Model









    YF

    Electromagnetic flowmeter


    TF

    Turbine


    VF

    Votex


    LX

    Vane wheel


    T

    Ultrasonic



    E/F display mode

    E: compact/local display, F: remote display




    Pipe Dia

    Type (mm)




    xxxx

    10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

    400, 500, 600, 800, 1000




    Code

    Accuracy




    1

    + 0.5% FS




    2

    + 1.0% FS




    3

    + 0.2% FS





    Code

    Type





    N

    Converter: 12 / 24 VDC, pulse output





    A

    Transmitter: 24VDC, 4-20mA outpt





    B

    Intelligent, Lion battery, no local display





    G

    Smart, local display, 4-20mA output





    C1

    Smart, local display, RS485





    C2

    Smart, local display, HART






    Code

    Type






    S

    Carbon steel housing






    L

    Stainless steel housing






    G

    High pressure housing






    HL

    316L electrode






    HTi

    Titanium electrode






    HTa

    Tantlum electrode






    HC

    Hastelloy-C electrode






    L1

    Liquid media






    L2

    Gas media






    P

    Pressure compensation






    T

    Temperature compensation






    PT

    Pressure&Temp. Compensation






    F

    PTFE liner






    X

    Rubber liner

    Sample: IYF-E-0100-1-C1-S-HL-L1-F,

    Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

    RS485, 316L electrode, liquid media meter, PTFE liner


    Competitive Advantage:

    • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
    • CE approval
    • Strict process control
    • Advanced calibration equipment
    • Engineer team

    Calibration

    Work shop

    Product Tags:

    magnetic flowmeter

      

    water flow meter

      
    Quality Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Xunhui Environment Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)